Description | APC 1500va Smart-Ups Rack Mount LCD 230V
- Intelligent and efficient network power protection from entry level to scaleable runtime. Ideal UPS for servers, point-of-sale, routers, switches, hubs, and others.
-
Includes: Installation guide, Rack Mounting support rails, USB cable.
| ALPHA 2KVA–1.6KW Off Grid Solar Inverter
• Pure sinwave solar inverter
• Output power factor : 1
• 12v system
• Maximum PV array power 2000W
• MPPT range operation voltage 30-400VDC
• Maximum charging current 80A
| Gamma 6 Hybrid                                                                                                                                                                                                                                                                               Technical features
MODEL Name – Gamma 6
Model Number – ONY-I-G6-48
Maximum PV Input Power – 6000W
Rated Output Power – 6000W | Crown Micro CMU-1200va UPS
- Capacity: 1200va/720W;
- Metal case;
- AC Voltage regulation;
- Short circuit protection;
- Overload protection;
- Battery overcharge protection;
- Surge protection;
- Overdischarge protection;
- Configuration: 12 V / 7.0 Ah × 2.
| Sollatek AVS13 Voltshield Appliance Guard
AVS13
Over & Under Voltage Protection for Laptops, Monitors, Fridges, Coolers, Media Centres & Satellites
Protect against
- High voltage
- Low voltage
- Spikes/surges
- Powerback surges
Ideal for
- All electrical and electronic equipment
Max current: 13 amps
Wait time: User adjustable from 10 seconds to 3 minutes
| Grovolt Ricco Plus 2.5KVA
* Pure Sine Wave Inverter
* Inbuilt With Transformer which is a strong load ability.
* Wide Charge Current 20-30A
* High-efficiency design & Power saving mode to conserve energy.
* Auto-restart when AC recovering.
|
Content |
APC 1500va Smart-Ups Rack Mount LCD 230V
- Cold-start capable
Provides temporary battery power when the utility power is out.
- Energy meter
Provides actual kilowatt hours of usage for energy-conscious users.
- Green mode
The patent-pending operating mode bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
- High online efficiency
Reduces utility costs, generates less heat.
- Intuitive LCD interface
Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy-to-use navigation keys.
- Predictive replace battery date
Dynamically provides the month and year when battery replacement is recommended to aid in long-term maintenance planning.
- Pure sine wave output on battery
Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.
- Single switched outlet group
Single outlet group that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off, and non-critical load shedding.
- SmartConnect
Innovative, easy-to-use remote monitoring feature that provides automatic notifications, firmware updates, and advanced support services.
- SmartSlot
Customize UPS capabilities with management cards.
- Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
APC 1500VA Smart-UPS, Rack Mount, LCD 230V with Smart Connect Port
Intelligent and efficient network power protection from entry level to scalable runtime. Ideal UPS for servers, point-of-sale, routers, switches, hubs and other network devices.
Includes: Documentation CD, Installation guide, Rack mounting brackets, USB cable
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Predictive failure notification.
Provides early-warning fault analysis ensuring proactive component replacement.
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Resettable circuit breakers
Enables a quick recovery from overload events.
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
| ALPHA 2KVA–1.6KW Off Grid Solar Inverter
Model name - Alpha 2KVA
Model Number - Ony-I-A1.6-12
Rated Power - 2000VA/1600W
AC Input Voltage - 230VAC
Selectble voltage - Computers (170-280VAC)/ Appliances (90-280VAC)
Frequency range 50/60Hz (Auto sensing)
AC Output
AC Voltage regular - 230VAC +/-5%
Surge power - 4000VA
Efficiency Peak - 98%
Transfer Time - 10ms
Battery & AC charger of ALPHA 2KVA–1.6KW Off Grid Solar Inverter                                                                                                                                                                                          Battery voltage - 12VDC
floating charge - 13.5VDC
Overcharge protection - 16VDC
Maximum Ac charge current - 60A
Solar charge
Maximum Pv Array power - 2000W
MPPT range operation voltage - 30-400VDC
Max PV array open circuit - 400VDC
Maximum charging current - 80A | Gamma 6 Hybrid
Technical features
MODEL Name – Gamma 6
Model Number – ONY-I-G6-48
Maximum PV Input Power – 6000W
Rated Output Power – 6000W
Gamma 6 Hybrid
• Pure sine wave output & Dual AC output
• Self-consumption and feed-in to the grid
• Built-in MPPT solar charger
• Programmable supply priority for PV, Battery or Grid
• User-adjustable charging current and voltage
• Programmable multiple operation modes: Grid-tie,off-grid and grid-tie with backup
• Detachable LCD panel
• Built-in Wi-Fi for mobile monitoring (APP is available)
• Supports USB on the go function
• Reserve BMS communication
• Parallel operation up to 9 units
SPECIFICATIONS
GRID TIE OPERATION (AC) / PV INPUT (DC) / HYBRID OPERATION
Power Rate/Nominal DC Voltage/Maximum DC Voltage - 360VDC/500VDC
Start-up Voltage/ Initial Feeding Voltage – 120VDC/150VDC
MPPT Voltage Range – 120VDC~150VDC/430VDC
Number of MPPT Trackers / Max Input Current - 1/27A
GRID TIE OPERATION / GRID OUTPUT (AC) / HYBRID OPERATION
Nominal Output Voltage - 220/230/240VAC
Output Voltage Range - 184 – 264.5 VAC or 195.5 – 253 VAC (Selectable)
Nominal Output Current - 26A
GRID TIE OPERATION / EFFICIENCY
Maximum Conversion Efficiency (DC/AC) - 95%
OFF-GRID OPERATION / AC INPUT / HYBRID OPERATION
AC Startup Voltage / Auto Restart Voltage – 120 - 140VAC / 180VAC
Acceptable Input Voltage Range - 90-280VAC or 170 - 280VAC
Frequency Range - 50Hz / 60Hz (Auto Sensing)
Maximum AC Input Current - 40A
OFF-GRID OPERATION / PV INPUT (DC)
Maximum DC Voltage - 500VDC
MPPT Voltage Range – 120VDC ~ 430VAC
Number of MPPT Trackers / Max Input Current - (1/27A)
OFF-GRID OPERATION / BATTERY MODE OUTPUT (AC)
Battery Mode Output (AC) - 220/230/240VAC
Output Waveform - Pure Sine Wave
Efficiency (DC to AC) - 93%
HYBRID OPERATION / BATTERY MODE OUTPUT
Nominal Output Voltage - 220/230/240VAC
Efficiency (DC to AC) - 93%
HYBRID OPERATION / BATTERY & CHARGER
Maximum DC Voltage - 48V
Maximum Solar Charging Current – 120A
Maximum AC Charging Current – 120A
Maximum Charging Current – 120A
GENERAL / PHYSICAL of Gamma 6 Hybrid
Dimension, D x W x H (mm) – 140 x 295 x 468
Net Weight – 14KG
GENERAL / INTERFACE
Parallel Function – Built in parallel kit up to 9 units
Communication Port – USB/RS-232/WiFi/Dry-Contact
GENERAL / ENVIRONMENT
Humidity – 0~ 90% RH (No Condensing)
Operating Temperature –  -10°C to 50°C | Powerful Crown Micro CMU-1200va UPS
The Powerful Crown Micro CMU-1200va UPS Uninterrupted Power Supply (UPS) has more capacity to meet your bigger load requirement.
With the Crown Micro CMU-1200va UPS, you are looking at backup time of over half an hour – enough time to tidy up your work and get it saved up.
The crown micro 1200va UPS which is a 1200va UPS, provides a power output rating of 720 watts, capable of supporting a set of office devices or some home appliances.
With the Crown Micro CMU-1200va UPS, you can be sure of power backup for the supported equipment, ensuring your work is protected in the event of sudden power failure.
It also enables you switch to alternative power supply, without sudden disruption.
The Crown Micro CMU-1200va UPS is suitable for use with computers, workstations, printers and other equipment within its capacity.
At home, It can support your televisions, music system, decoder, PCs, internet modem.
Specifications:
Technology:
UPS type |
Off-Line |
Form factor |
Tower |
Input parameters:
Power |
480 VA |
Current frequency |
(50/60)±1Hz (Frequency self-adapt system) |
Output parameters:
Output voltage |
220 / 230V ± 10% |
Form voltage |
Stepped approximation to a sinewave |
Current frequency |
50/60 Hz ± 1% |
Switching time |
2-4 ms, including the determination of the time |
Automatic voltage regulation (AVR) |
1 step down, two steps up |
Protection and UPS equipment:
Surge Protection |
Yes |
Overloads protectio |
110% < Load percentage <120%, buzze beeps; load percentage >120%. output shuts off, buzzer beeps continuosly |
Protection for UPS input |
Fuse for overload protection and short circuit protection |
UPS protection for short circuit |
Immediate shutdown of the UPS using the input fuse |
Protect the phone, fax, modem, LAN |
No |
| Specification
Max Power 13 Amps
Wait Time Adjustable from 15 Seconds to 3 Minutes
Ideal For All electrical and electronic equipment
Weight 500 gm
Dimensions 205 x 135 x 55mm
| GROVALT RICCO PLUS 2.5KVA
Grovolt Ricco Plus 2.5KVA (12/24/48V) Off Grid Solar Inverter
* Pure Sine Wave Inverter
* Inbuilt With Transformer which is a strong load ability.
* Wide Charge Current 20-30A
* High-efficiency design & Power saving mode to conserve energy.
* Auto-restart when AC recovering.
* Smart battery charger design for optimized battery performance; With bypass /battery reverse protection / 6mill seconds transfer time / surge protection/input & output overload protection
DESCRIPTION
SPECIFICATIONS of GROVALT RICCO PLUS 2.5KVA
Model name – RP-2500
Input
Capacity – 2500VA
Voltage (DC) – 12/24/48V
Nominal Voltage – 220VAC/110VAC
Voltage Range – 154-265VAC/77-135VAC
Frequency 50/60Hz (Auto sensing)
OUTPUT
Watt 800W | 1200W | 2000W | 2800W | 4000W | 4800W | 5200W | 6400W | 8000W
Voltage – 220VAC/110VAC
Frequency - 50Hz to 60Hz
Waveform – Pure Sinewave
Transfer time (AC to DC) <8ms
Transfer time (DC to AC) <8ms
Output Voltage Regulation 10%rms
Bypass Mode Yes
Save mode Yes
Efficiency >98%
PROTECTION
Input protection Circuit breaker
Output protection Circuit breaker
BATTERY
BATTERY TYPE AGM- Deep Cycle Gel
Up to 500Ah
Charging current 20/10A |30/15/7A | 48/24/12A | 30/15A | 40/20A | 45/22A | 50/25A | 35A | 50/25/12A
Low level disconnect (10V or 10.5V) × N N means the number of batteries in series
LCD INDICATOR STATUS Input AC/ Output AC
Battery DC, Output Load
Alarm, Fault
Battery Charge Level
Output Frequency
LED INDICATOR STATUS AC Line in: Green
Inverter: Green
Charging: Yellow
Alarm: Red
GROVALT RICCO PLUS 2.5KVAÂ Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Battery low alarm battery light discharge 11.5V*N; battery load discharge 11.5V*N@load<20%
11V*N@load>50% / 10.5V*N@load>50%
Battery low recovery battery light discharge 11.5V*N; battery load discharge 11.5V*N@load<20%
11.5V*N@load>50% / 11V*N@load>50%
DC low voltage shutdown battery light discharge 11.5V*N; battery load discharge 11.5V*N@load<20%
10.5V*N@load>50% / 10.5V*N@load>50%
DC high Voltage alarm & fault 16V*N
DC high Voltage recovery 15V*N
ALARM
Low battery alarm Audible alarm -1 beeping per second
Overload alarm Audible alarm-continuous beeping
Fault Audible alarm-continuous beeping
ENVIRONMENT
Temperature - (0 - 40)
Humidity - CO-95% Non Condensing
Fault – >55db |