Content |
APC 3000va Smart-Ups Tower LCD 230V
Run time for load
Min-max: 270-2700 W
Output Connections
(8) IEC 320 C13 (Battery Backup)
(1) IEC 320 C19 (Battery Backup)
(2) IEC Jumpers (Battery Backup)
APC 3000va Smart-Ups Tower LCD 230V Input Connections
BS1363A British, IEC 320 C20, Schuko CEE 7 / EU1-16P
APC 3000VA Smart-UPS ,Tower, LCD 230V with SmartConnect Port
Intelligent and efficient network power protection from entry level to scalable runtime. Ideal UPS for servers, point-of-sale, routers, switches, hubs and other network devices.
Includes:Â USB cable
- Cold-start capable
Provides temporary battery power when the utility power is out.
- Energy meter
Provides actual kilowatt hours of usage for energy conscious users.
- Green mode
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
- High online efficiency
Reduces utility costs, generates less heat.
- Intuitive LCD interface
Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.
- Predictive replace battery date
Dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.
- Pure sine wave output on battery
Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.
- Sequenced network shutdown and reboot
Customize network shutdown and reboot sequence of connected servers and UPSs.
- Single switched outlet group
Single outlet group that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.
- SmartConnect
Innovative, easy to use remote monitoring feature that provides automatic notifications, firmware updates, and advanced support services.
- SmartSlot
Customize UPS capabilities with management cards.
- StruxureWare Data Center Expert compatible
Enables centralized management via StruxureWare Data Center Expert.
- Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Predictive failure notification.
Provides early-warning fault analysis ensuring proactive component replacement.
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Resettable circuit breakers
Enables a quick recovery from overload events.
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Peace of mind that comes with full equipment compatibility and reliability of a leader
Provides pure sine wave output which is recommended by server manufacturers using active power factor corrected (PFC) power supplies. Safety agency tested and approved means that you can deploy Smart-UPS with confidence that they meet or exceed the industry’s most rigorous standards.
Smarter productivity with ability to tailor to your specific application needs
Intuitive LCD interface provides clear information with the ability to configure the UPS locally with easy to use navigation keys. Over 15 different programmable settings including switched outlet group control allow for application specific settings, thresholds and notifications.
Low operating and maintenance costs with high efficiency, proven reliability and intelligent battery management
Patented green operating mode achieves efficiencies over 97%. Smart-ups was the first network UPS to be Energy Star certified. Intelligent battery management, pioneered by APC, maximizes battery performance and life through intelligent, precision temperature compensated charging. Dynamic battery replacement date indicator and automatic self tests insure battery reliability and warn in advance of needing replacement. Convenient, easy to connect, hot-swappable battery modules provide battery replacement without powering down. Designed and manufactured by APC for over 23 years, Smart-UPS is the world’s most trusted network UPS with over 25 million units sold.
Save time with easy and convenient remote accessibility
Network manageable via serial, USB or optional ethernet. Includes Powerchute® Business Edition Software for convenient monitoring and control, safe operating system shutdown and innovative energy management capabilities.
Avoids costly power problems by keeping your IT equipment and data safe and available
Network grade power conditioning protects from damaging surges and disruptive noise. Solid state automatic voltage regulation boosts low input voltage up to 30% and trims high voltage up to 12% without battery operation. Reliable battery back-up capacity to power through outages or gracefully shutdown systems
Audible alarms
Provides notification of changing utility power and UPS conditions.
Network manageable
Most models provide remote power management options of the UPS over the network. Many do not have NMC embedded.
LED status indicators
Quickly understand unit and power status with visual indicators.
USB connectivity
Provides management of the UPS via a USB port (not available on all models).
Serial connectivity
Provides management of the UPS via a serial port.
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Automatic restart of loads after UPS shutdown
 APC 3000va Smart-Ups Tower LCD 230V Automatically starts up the connected equipment upon the return of utility power.
Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Adjustable voltage-transfer points
 APC 3000va Smart-Ups Tower LCD 230V Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
Adjustable voltage sensitivity
Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
United Arab Emirates, Afghanistan, Albania, Armenia, Angola, Austria, Australia, Azerbaijan, Bosnia and Herzegovina, Belgium, Burkina Faso, Bahrain, Burundi, Benin, Botswana, The Democratic Republic Of Congo, Switzerland, Côte d'Ivoire, Chile, Cameroon, Serbia and Montenegro, Cyprus, Czech Republic, Germany, Djibouti, Denmark, Algeria, Estonia, Egypt, Eritrea, Spain, Ethiopia, Finland, Fiji, France, Gabon, Ghana, Gambia, Greece, Hong Kong, Croatia, Hungary, Indonesia, Ireland, Israel, Iraq, Iceland, Italy, Jordan, Kenya, Cambodia, South Korea, Kuwait, Lebanon, Liberia, Lithuania, Luxembourg, Latvia, Madagascar, Macedonia, Mali, Mongolia, Mauritania, Malta, Mauritius, Malawi, Malaysia, Mozambique, Namibia, Nigeria, Netherlands, Norway, New Zealand, Oman, Peru, Philippines, Pakistan, Poland, Portugal, Qatar, Reunion, Romania, Rwanda, Saudi Arabia, Sweden, Singapore, Slovenia, Slovakia, Sierra Leone, Senegal, Somalia, Togo, Thailand, Tunisia, Turkey, Taiwan, Tanzania, Ukraine, Vietnam, Yemen, Mayotte, South Africa, Zambia, Zimbabwe
Max Configurable Power (Watts)
Output Voltage Note
Configurable for 220 : 230 or 240 nominal output voltage
 APC 3000va Smart-Ups Tower LCD 230V Output Voltage Distortion
Output Frequency (sync to mains)
50/60 Hz +/- 3 Hz Sync to mains
Transfer Time
6 ms typical : 10 ms maximum
Input frequency
50/60 Hz +/- 3 Hz Auto-sensing
Input voltage range for main operations
151 - 302 Adjustable, 160 - 286V
Expected Battery Life (years)
Battery Charge Power (Watts)
Control panel
Multifunction LCD status and control console
Audible Alarm
Alarm when on battery : distinctive low battery alarm : configurable delays
Emergency Power Off (EPO)
Available SmartSlotâ„¢ Interface Quantity
Filtering
Full time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL 1449
Operating Relative Humidity
Storage Relative Humidity
Audible noise at 1 meter from surface of unit
Online thermal dissipation
Approvals
CE, EAC, EN/IEC 62040-1, EN/IEC 62040-2, RCM, VDE
Standard warranty
3 years repair or replace (excluding battery) and 2 years for battery, optional on-site warranties available, optional extended warranties available
| Beta 4.2 Hybrid Solar Inverter
Model name Beta 4.2KW
Max PV input Power - 6200
Rated output power - 4200
Maximum solar charger power - 140A
Grid Tie operation / PV input (DC)
Nominal DC voltage/ Max DC voltage - 360VvDC/500VDC
Start up Voltage/ Initial feeding voltage - 90DVC/120VDC
MPPT voltage range - 90-450VDC
Number of MPPT trackers / Max input current - 1/27A
Grid output (AC)
Nominal output voltage - 220/230/240VAC
output voltage range - 195-235VAC
Nominal output current - 18.2A
Power factor - 0.99
Feed-in Grid frequency range - 49Hz to 51Hz
Efficiency - 97%
Off-Grid operation / AC input
AC startup voltage / Auto restarting voltage - 120-140V
Acceptable input voltage range - 90-280VAC/ 170-280VAC
Maximum AC input Current - 30A
Nominal operating frequency 50/60Hz
Surge power - 8400VA
Off-Grid operation / PV input(DC)
Maximum DC voltage - 500vVDC
MPPT voltage range - 90-450VAC
Number of MPPT trackers / Max input current - (1/27)
Battery mode output AC
Nominal output voltage - 24V
Output wave form - Pure sin wave
Efficiency (DC to AC) - 94%
Battery & charger
Nominal DC voltage -24V
Maximum solar charger current - 140A
Maximum AC charging current - 100A
Physical features
Dimensions (D*Y*H) - 420 * 310 * 110
Net Weight (KGs) - 9.5
Interface - serial connection
communications - RS-232
Humidity - 0-90%
Operating temperature - (-10 to 50) | Grovolt Ricco Plus 3.5KVA (24/48V)
* Pure Sine Wave Inverter
* Inbuilt With Transformer which is a strong load ability.
* Wide Charge Current 20-30A
* High-efficiency design & Power saving mode to conserve energy.
* Auto-restart when AC recovering.
* Smart battery charger design for optimized battery performance; With bypass /battery reverse protection / 6mill seconds transfer time / surge protection/input & output overload protection
DESCRIPTION
SPECIFICATIONS of Grovolt Ricco Plus 3.5KVA (24/48V)
Model name – RP-3500 AND RP-3548
Input
Capacity – 3500VA
Voltage (DC) – 24/48V
Nominal Voltage – 220VAC/110VAC
Voltage Range – 154-265VAC/77-135VAC
Frequency 50/60Hz (Auto sensing)
OUTPUT
Watt 800W | 1200W | 2000W | 2800W | 4000W | 4800W | 5200W | 6400W | 8000W
Voltage – 220VAC/110VAC
Frequency - 50Hz to 60Hz
Waveform – Pure Sinewave
Transfer time (AC to DC) <8ms
Transfer time (DC to AC) <8ms
Output Voltage Regulation 10%rms
Bypass Mode Yes
Save mode Yes
Efficiency >98%
PROTECTION
Input protection Circuit breaker
Output protection Circuit breaker
BATTERY
BATTERY TYPE AGM- Deep Cycle Gel
Up to 500Ah
Charging current 20/10A |30/15/7A | 48/24/12A | 30/15A | 40/20A | 45/22A | 50/25A | 35A | 50/25/12A
Low level disconnect (10V or 10.5V) × N N means the number of batteries in series
LCD INDICATOR STATUS Input AC/ Output AC
Battery DC, Output Load
Alarm, Fault
Battery Charge Level
Output Frequency
LED INDICATOR STATUS AC Line in: Green
Inverter: Green
Charging: Yellow
Alarm: Red
Grovolt Ricco Plus 3.5KVA (24/48V)
Battery low alarm battery light discharge 11.5V*N; battery load discharge 11.5V*N@load<20%
11V*N@load>50% / 10.5V*N@load>50%
Battery low recovery battery light discharge 11.5V*N; battery load discharge 11.5V*N@load<20%
11.5V*N@load>50% / 11V*N@load>50%
DC low voltage shutdown battery light discharge 11.5V*N; battery load discharge 11.5V*N@load<20%
10.5V*N@load>50% / 10.5V*N@load>50%
DC high Voltage alarm & fault 16V*N
DC high Voltage recovery 15V*N
ALARM
Low battery alarm Audible alarm -1 beeping per second
Overload alarm Audible alarm-continuous beeping
Fault Audible alarm-continuous beeping
ENVIRONMENT
Temperature - (0 - 40)
Humidity - CO-95% Non Condensing
Fault – >55db | This Blue Gate 2KVA Stabilizer AVR series has adopted advanced control technology made with reliable components. It is a new type of AC automatic regulator with a fully automatic control system. It has the features of a wide input voltage range, high reliability, more stabilized output voltage, energy saving, etc.
The Blue Gate 2KVA Stabilizer AVR has been designed to offer superior protection to your appliances against ups and downs in voltage. Fluctuations in voltage have a way of affecting electronic devices, so it is essential for you to use a high-performance stabilizer like Blue Gate 2KVA Stabilizer. It will save you the stress of visiting technicians to fix faulty parts frequently. Applications It can be used to supply stabilized power to lights, Television, air-conditioner, refrigerator, computer and duplicating machines, and other household equipment; Schools, offices, hotels, etc it makes your appliances work on the both high and low voltage when you use this efficient stabilizer. You can also grab other power product deals at the lowest prices only on EscapadeNg. Buy Escapade Nigeria at the best price.
A world-class brand of alternative power solutions, Blue Gate is owned by Triplesea Limited, an indigenous Nigerian Alternative Power Solutions company. For Blue Gate, the aim is to provide durable products through a complete process that spans from idea generation to after-sales support. Blue Gate delivers integrated solutions that meet the exact standards of excellence in global power systems in the alternative power sector with products that include high-capacity online UPS, line interactive UPS, Off-Line UPS, inverters, stabilizers (AVR), and inverter batteries.
| Delta 8.2 Hybrid
Technical features
MODEL Name - Delta 8.2
Model Number - ONY-I-D8.2-48
Rated Power - 8200VA/8200W
PARALLEL CAPABILITY - Yes, up to 6 units
Delta 8 Hybrid
• Operation Type: Off-Grid/On-Grid
• Sine wave Type: Pure, Power Factor 1.0
• Dual AC output for smart load management
• Battery Independent Design
• Wide PV input voltage range (90-450VDC)
• Built-in WiFi with IOS & Android APP
• Supports USB on the go function
• RGB Lightning for different working modes (Battery, Solar, Utility)
• With Parallel kits support up to 6 units
INPUT
Voltage - 230 VAC
Selectable Voltage Range - 170-280 VAC (For Personal Computers)/90-280 VAC (For Home Appliances)
Frequency Range - 50 Hz/60 Hz (Auto sensing)
OUTPUT
AC Voltage Regulation (Batt.Mode) - 230VAC+/-5%
Surge Power - 16400VA
Efficiency (Peak) - 90% ~ 93%
Transfer Time - 15 ms (For Personal Computers) ; 20 ms (For Home Appliances)
Waveform - Pure sine wave
No Load Power Consumption - <70wW
DC Voltage (Optional) - 12 VDC +/- 5%,100W
BATTERY
Battery Voltage - 48 VDC
Floating Charge Voltage - 54 VDC
Overcharge Protection - 66 VDC
SOLAR CHARGER & AC CHARGER of Delta 8.2 Hybrid
Solar Charger Type – MPPT
Maximum PV Array Power – 8200W (4100W x 2)
MPPT Range @ Operating Voltage – 90 ~ 450 VDC
Maximum PV Array Open Circuit Voltage – 500 VDC
Maxmum Solar Charge Current – 120 A
Maximum AC Charge Current – 120 A
Maximum Charge Current – 120 A
PHYSICAL
Dimension, D x W x H (mm) – 147.4 x 432.5 x 553.6
Net Weight (kgs) – 18.4
Communication Interface – USB/RS232/RS485/WiFi/Dry-contact
OPERATING ENVIRONMENT
Humidity: 5% to 95% to Relative Humidity (Non-Condensing)
Operating Temperature – 10°C to 50°C
Storage Temperature – 15°C to 60°C
Compliance Safety – CE
| Beta 6.2 Hybrid Solar Inverter
Model name Beta 6.2KW
Max PV input Power - 6500
Rated output power - 6200
Maximum solar charger power - 120A
Grid Tie operation / PV input (DC)
Nominal DC voltage/ Max DC voltage - 360VvDC/500VDC
Start up Voltage/ Initial feeding voltage - 90DVC/120VDC
MPPT voltage range - 90-450VDC
Number of MPPT trackers / Max input current - 1/27A
Grid output (AC)
Nominal output voltage - 220/230/240VAC
output voltage range - 195-235VAC
Nominal output current - 27A
Power factor - 0.99
Feed-in Grid frequency range - 49Hz to 51Hz
Efficiency - 97%
Off-Grid operation / AC input
AC startup voltage / Auto restarting voltage - 180V
Acceptable input voltage range - 90-280VAC/ 170-280VAC
Maximum AC input Current - 40A
Nominal operating frequency 50/60Hz
Surge power - 12400VA
Off-Grid operation / PV input(DC)
Maximum DC voltage - 500vVDC
MPPT voltage range - 90-450VAC
Number of MPPT trackers / Max input current - (1/27)
Battery mode output AC
Nominal output voltage - 48V
Output wave form - Pure sin wave
Efficiency (DC to AC) - 94%
Battery & charger
Nominal DC voltage -48V
Maximum solar charger current - 120A
Maximum AC charging current - 100A
Physical features
Dimensions (D*Y*H) - 420 * 310 * 110
Net Weight (KGs) - 10.5
Interface - serial connection
communications - RS-232
Humidity - 0-90%
Operating temperature - (-10 to 50) |
Reviews
There are no reviews yet.