Description | Ricco Plus Inverter 1.5KVA / 1,200W / 24V
- It has a Pure sine wave Inverter.
- Inbuilt With Transformer which is a strong load ability.
- Wide charge current 20-30A.
- High-efficiency design & Power saving mode to conserve energy.
- Auto-restart when Ac recovering.
| APC EASY UPS BV 650VA
- Output power capacity: 375 Watts / 650 VA
- Max Configurable Power (Watts): 375 Watts / 650 VA
- Nominal Output Voltage: 230V
- Output Frequency (not synced): 50/60 Hz +/-1 Hz
| Gamma 6 Hybrid                                                                                                                                                                                                                                                                               Technical features
MODEL Name – Gamma 6
Model Number – ONY-I-G6-48
Maximum PV Input Power – 6000W
Rated Output Power – 6000W | ALPHA 2KVA–1.6KW Off Grid Solar Inverter
• Pure sinwave solar inverter
• Output power factor : 1
• 12v system
• Maximum PV array power 2000W
• MPPT range operation voltage 30-400VDC
• Maximum charging current 80A
| ALPHA 3.2KVA–3KW Off Grid
• Pure Sine wave Solar Inverter
• Output power factor : 0.8
• 24v system
• Maximum PV array power 3000W
• MPPT Range Operation Voltage 30-400VDC
• Maximum Charging Current 80A | Grovolt Ricco Plus 2.5KVA
* Pure Sine Wave Inverter
* Inbuilt With Transformer which is a strong load ability.
* Wide Charge Current 20-30A
* High-efficiency design & Power saving mode to conserve energy.
* Auto-restart when AC recovering.
|
Content | Ricco Plus Inverter 1.5KVA / 1,200W / 24V
Ricco plus inverter has a Pure sine wave Inverter.
Inbuilt With Transformer which is a strong load ability.
Ricco plus inverter has a wide charge current 20-30A
High-efficiency design & Power saving mode to conserve energy.
Ricco plus inverter has Auto-restart when Ac recovering.
Smart battery charger design for optimized battery performance ;
Ricco plus inverter come with a bypass /battery reverse protection /
6mill seconds transfer time / surge protection/input & output overload protection. | APC EASY UPS BV 650VA
APC EASY UPS BV 650VA, AVR, Universal Outlet, 230V
Best Value UPS with Battery Backup & Surge Protection for Electronics and Computers
Output
Max Configurable Power (Watts):375Watts / 650VA
Output Frequency (not synced):50/60 Hz +/-1 Hz
Topology:Line Interactive
Waveform type: Stepped approximation to a sinewave
Transfer Time:6ms typical : 10ms maximum
Input
Input frequency:50/60 Hz +/- 5 Hz (auto sensing)
Number of Power Cords:1
Batteries & Runtime
Battery type:Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
Expected Battery Life (years):3 – 5
Communications & Management
Control panel:LED Status display with On Line : On Battery
Audible Alarm: Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm
Net Weight:4.5KG
FEATURES OF APC EASY UPS BV 650VA
- Provides temporary battery power when the utility power is out
- Protect equipment with input transformer blocks without blocking access to other receptacles.
- Slim, modern design can be upright, flat, or wall-mounted to comfortably fit any electronics set-up and complement home décor.
- Preserves battery life and maximizes runtime by correcting low voltages without discharging the battery.
| Gamma 6 Hybrid
Technical features
MODEL Name – Gamma 6
Model Number – ONY-I-G6-48
Maximum PV Input Power – 6000W
Rated Output Power – 6000W
Gamma 6 Hybrid
• Pure sine wave output & Dual AC output
• Self-consumption and feed-in to the grid
• Built-in MPPT solar charger
• Programmable supply priority for PV, Battery or Grid
• User-adjustable charging current and voltage
• Programmable multiple operation modes: Grid-tie,off-grid and grid-tie with backup
• Detachable LCD panel
• Built-in Wi-Fi for mobile monitoring (APP is available)
• Supports USB on the go function
• Reserve BMS communication
• Parallel operation up to 9 units
SPECIFICATIONS
GRID TIE OPERATION (AC) / PV INPUT (DC) / HYBRID OPERATION
Power Rate/Nominal DC Voltage/Maximum DC Voltage - 360VDC/500VDC
Start-up Voltage/ Initial Feeding Voltage – 120VDC/150VDC
MPPT Voltage Range – 120VDC~150VDC/430VDC
Number of MPPT Trackers / Max Input Current - 1/27A
GRID TIE OPERATION / GRID OUTPUT (AC) / HYBRID OPERATION
Nominal Output Voltage - 220/230/240VAC
Output Voltage Range - 184 – 264.5 VAC or 195.5 – 253 VAC (Selectable)
Nominal Output Current - 26A
GRID TIE OPERATION / EFFICIENCY
Maximum Conversion Efficiency (DC/AC) - 95%
OFF-GRID OPERATION / AC INPUT / HYBRID OPERATION
AC Startup Voltage / Auto Restart Voltage – 120 - 140VAC / 180VAC
Acceptable Input Voltage Range - 90-280VAC or 170 - 280VAC
Frequency Range - 50Hz / 60Hz (Auto Sensing)
Maximum AC Input Current - 40A
OFF-GRID OPERATION / PV INPUT (DC)
Maximum DC Voltage - 500VDC
MPPT Voltage Range – 120VDC ~ 430VAC
Number of MPPT Trackers / Max Input Current - (1/27A)
OFF-GRID OPERATION / BATTERY MODE OUTPUT (AC)
Battery Mode Output (AC) - 220/230/240VAC
Output Waveform - Pure Sine Wave
Efficiency (DC to AC) - 93%
HYBRID OPERATION / BATTERY MODE OUTPUT
Nominal Output Voltage - 220/230/240VAC
Efficiency (DC to AC) - 93%
HYBRID OPERATION / BATTERY & CHARGER
Maximum DC Voltage - 48V
Maximum Solar Charging Current – 120A
Maximum AC Charging Current – 120A
Maximum Charging Current – 120A
GENERAL / PHYSICAL of Gamma 6 Hybrid
Dimension, D x W x H (mm) – 140 x 295 x 468
Net Weight – 14KG
GENERAL / INTERFACE
Parallel Function – Built in parallel kit up to 9 units
Communication Port – USB/RS-232/WiFi/Dry-Contact
GENERAL / ENVIRONMENT
Humidity – 0~ 90% RH (No Condensing)
Operating Temperature –  -10°C to 50°C | ALPHA 2KVA–1.6KW Off Grid Solar Inverter
Model name - Alpha 2KVA
Model Number - Ony-I-A1.6-12
Rated Power - 2000VA/1600W
AC Input Voltage - 230VAC
Selectble voltage - Computers (170-280VAC)/ Appliances (90-280VAC)
Frequency range 50/60Hz (Auto sensing)
AC Output
AC Voltage regular - 230VAC +/-5%
Surge power - 4000VA
Efficiency Peak - 98%
Transfer Time - 10ms
Battery & AC charger of ALPHA 2KVA–1.6KW Off Grid Solar Inverter                                                                                                                                                                                          Battery voltage - 12VDC
floating charge - 13.5VDC
Overcharge protection - 16VDC
Maximum Ac charge current - 60A
Solar charge
Maximum Pv Array power - 2000W
MPPT range operation voltage - 30-400VDC
Max PV array open circuit - 400VDC
Maximum charging current - 80A | ALPHA 3.2KVA–3KW Off Grid
• Pure Sine wave Solar Inverter
• Output power factor : 0.8
• 24v system
• Maximum PV array power 3000W
• MPPT Range Operation Voltage 30-400VDC
• Maximum Charging Current 80A
ALPHA 3.2KVA–3KW Off Grid
Model name – Alpha 3.2KVA
Model Number – Ony-I-A3.0-24
Rated Power – 3200VA/300W
AC Input Voltage – 230VAC
Selectable Voltage – Computers (170-280VAC)/ Appliances (90-280VAC)
Frequency range 50/60Hz (Auto sensing)
AC OUTPUT
AC Voltage Regulation – 230VAC +/-5%
Surge Power – 6400VA
Efficiency Peak – 98%
Transfer Time – 10ms
BATTERY & AC CHARGER
Battery Voltage – 24VDC
Floating Charge – 27VDC
Overcharge Protection – 33VDC
Maximum AC Charge Current – 60A
SOLAR CHARGER
Maximum PV Array power – 3000W
MPPT Range Operation Voltage – 30-400VDC
Max PV array open circuit – 400VDC
Maximum Charging Current – 80A | GROVALT RICCO PLUS 2.5KVA
Grovolt Ricco Plus 2.5KVA (12/24/48V) Off Grid Solar Inverter
* Pure Sine Wave Inverter
* Inbuilt With Transformer which is a strong load ability.
* Wide Charge Current 20-30A
* High-efficiency design & Power saving mode to conserve energy.
* Auto-restart when AC recovering.
* Smart battery charger design for optimized battery performance; With bypass /battery reverse protection / 6mill seconds transfer time / surge protection/input & output overload protection
DESCRIPTION
SPECIFICATIONS of GROVALT RICCO PLUS 2.5KVA
Model name – RP-2500
Input
Capacity – 2500VA
Voltage (DC) – 12/24/48V
Nominal Voltage – 220VAC/110VAC
Voltage Range – 154-265VAC/77-135VAC
Frequency 50/60Hz (Auto sensing)
OUTPUT
Watt 800W | 1200W | 2000W | 2800W | 4000W | 4800W | 5200W | 6400W | 8000W
Voltage – 220VAC/110VAC
Frequency - 50Hz to 60Hz
Waveform – Pure Sinewave
Transfer time (AC to DC) <8ms
Transfer time (DC to AC) <8ms
Output Voltage Regulation 10%rms
Bypass Mode Yes
Save mode Yes
Efficiency >98%
PROTECTION
Input protection Circuit breaker
Output protection Circuit breaker
BATTERY
BATTERY TYPE AGM- Deep Cycle Gel
Up to 500Ah
Charging current 20/10A |30/15/7A | 48/24/12A | 30/15A | 40/20A | 45/22A | 50/25A | 35A | 50/25/12A
Low level disconnect (10V or 10.5V) × N N means the number of batteries in series
LCD INDICATOR STATUS Input AC/ Output AC
Battery DC, Output Load
Alarm, Fault
Battery Charge Level
Output Frequency
LED INDICATOR STATUS AC Line in: Green
Inverter: Green
Charging: Yellow
Alarm: Red
GROVALT RICCO PLUS 2.5KVAÂ Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Battery low alarm battery light discharge 11.5V*N; battery load discharge 11.5V*N@load<20%
11V*N@load>50% / 10.5V*N@load>50%
Battery low recovery battery light discharge 11.5V*N; battery load discharge 11.5V*N@load<20%
11.5V*N@load>50% / 11V*N@load>50%
DC low voltage shutdown battery light discharge 11.5V*N; battery load discharge 11.5V*N@load<20%
10.5V*N@load>50% / 10.5V*N@load>50%
DC high Voltage alarm & fault 16V*N
DC high Voltage recovery 15V*N
ALARM
Low battery alarm Audible alarm -1 beeping per second
Overload alarm Audible alarm-continuous beeping
Fault Audible alarm-continuous beeping
ENVIRONMENT
Temperature - (0 - 40)
Humidity - CO-95% Non Condensing
Fault – >55db |