Description | Blue Gate 1500VA UPS
- Lightening and surge protection
- Short circuit and overload protection
- Energy saving function with UPS green mode
- Line Interactive design
- Fully digitized microprocessor controlled
- SMD technology
- Wide input voltage and frequency window Boost and buck AVR
- Three(3) LED indication for easy understanding
| Grovolt Ricco Plus 3.5KVA (24/48V)
* Pure Sine Wave Inverter
* Inbuilt With Transformer which is a strong load ability.
* Wide Charge Current 20-30A
* High-efficiency design & Power saving mode to conserve energy.
* Auto-restart when AC recovering. | Crown Micro CMU-1200va UPS
- Capacity: 1200va/720W;
- Metal case;
- AC Voltage regulation;
- Short circuit protection;
- Overload protection;
- Battery overcharge protection;
- Surge protection;
- Overdischarge protection;
- Configuration: 12 V / 7.0 Ah × 2.
| Gamma 6 Hybrid                                                                                                                                                                                                                                                                               Technical features
MODEL Name – Gamma 6
Model Number – ONY-I-G6-48
Maximum PV Input Power – 6000W
Rated Output Power – 6000W | Beta 4.2 Hybrid Solar Inverter
• Pure sine wave inverter
• Output power factor:1
• Battery independent design
• RGB lighting for different operation modes
• OFF/ON Grid Operation types
• Built-in 120 /140Ah solar charger
• High PV input range (90VDC to 500VC)
• Max PV input power 6200 | BLUE GATE 1530KVA UPS
- It has 900W rated power output capacity
- Dependable, Rugged design
- Fully digitized microprocessor control for top performance
- Wide input voltage & frequency range
- High performance SMD technology; Boost & buck AVR
- Intelligent battery management
- 3 LED indicators'
- Lightening & surge protection; Short circuit & overload protection
- Plastic Casing
|
Content | Â Blue Gate 1500VA UPS is efficient, durable and boasts of three LED indications that make it easy for you to understand as well as a
digitized microprocessor control that stabilizes the flow of power and overload protection that makes it not to affect any of your household appliances.
The energy saving function comes in a green and red color mode that lets you know when the UPS battery is full and
when it is also getting low to enable you switch off your appliances before it finally shut off.
Blue Gate 1500VA UPS that provides an alternative power supply to connects with any electronic equipment when the primary power source is not available.
You could make use of the UPS for your electrical equipment with generators that are compatible with the voltage of the
UPS to enjoy your television, freezers, air conditioners and more without fluctuation of supply of power.
The UPS charges manually and automatically as you are making use of it when there is stable light or
with generator and is helpful in protecting our appliances from damages and have prevents serious hardware damage and
data loss when working seriously and focusing on your work without minding the blackout of power supply or fluctuations.
| Grovolt Ricco Plus 3.5KVA (24/48V)
* Pure Sine Wave Inverter
* Inbuilt With Transformer which is a strong load ability.
* Wide Charge Current 20-30A
* High-efficiency design & Power saving mode to conserve energy.
* Auto-restart when AC recovering.
* Smart battery charger design for optimized battery performance; With bypass /battery reverse protection / 6mill seconds transfer time / surge protection/input & output overload protection
DESCRIPTION
SPECIFICATIONS of Grovolt Ricco Plus 3.5KVA (24/48V)
Model name – RP-3500 AND RP-3548
Input
Capacity – 3500VA
Voltage (DC) – 24/48V
Nominal Voltage – 220VAC/110VAC
Voltage Range – 154-265VAC/77-135VAC
Frequency 50/60Hz (Auto sensing)
OUTPUT
Watt 800W | 1200W | 2000W | 2800W | 4000W | 4800W | 5200W | 6400W | 8000W
Voltage – 220VAC/110VAC
Frequency - 50Hz to 60Hz
Waveform – Pure Sinewave
Transfer time (AC to DC) <8ms
Transfer time (DC to AC) <8ms
Output Voltage Regulation 10%rms
Bypass Mode Yes
Save mode Yes
Efficiency >98%
PROTECTION
Input protection Circuit breaker
Output protection Circuit breaker
BATTERY
BATTERY TYPE AGM- Deep Cycle Gel
Up to 500Ah
Charging current 20/10A |30/15/7A | 48/24/12A | 30/15A | 40/20A | 45/22A | 50/25A | 35A | 50/25/12A
Low level disconnect (10V or 10.5V) × N N means the number of batteries in series
LCD INDICATOR STATUS Input AC/ Output AC
Battery DC, Output Load
Alarm, Fault
Battery Charge Level
Output Frequency
LED INDICATOR STATUS AC Line in: Green
Inverter: Green
Charging: Yellow
Alarm: Red
Grovolt Ricco Plus 3.5KVA (24/48V)
Battery low alarm battery light discharge 11.5V*N; battery load discharge 11.5V*N@load<20%
11V*N@load>50% / 10.5V*N@load>50%
Battery low recovery battery light discharge 11.5V*N; battery load discharge 11.5V*N@load<20%
11.5V*N@load>50% / 11V*N@load>50%
DC low voltage shutdown battery light discharge 11.5V*N; battery load discharge 11.5V*N@load<20%
10.5V*N@load>50% / 10.5V*N@load>50%
DC high Voltage alarm & fault 16V*N
DC high Voltage recovery 15V*N
ALARM
Low battery alarm Audible alarm -1 beeping per second
Overload alarm Audible alarm-continuous beeping
Fault Audible alarm-continuous beeping
ENVIRONMENT
Temperature - (0 - 40)
Humidity - CO-95% Non Condensing
Fault – >55db | Powerful Crown Micro CMU-1200va UPS
The Powerful Crown Micro CMU-1200va UPS Uninterrupted Power Supply (UPS) has more capacity to meet your bigger load requirement.
With the Crown Micro CMU-1200va UPS, you are looking at backup time of over half an hour – enough time to tidy up your work and get it saved up.
The crown micro 1200va UPS which is a 1200va UPS, provides a power output rating of 720 watts, capable of supporting a set of office devices or some home appliances.
With the Crown Micro CMU-1200va UPS, you can be sure of power backup for the supported equipment, ensuring your work is protected in the event of sudden power failure.
It also enables you switch to alternative power supply, without sudden disruption.
The Crown Micro CMU-1200va UPS is suitable for use with computers, workstations, printers and other equipment within its capacity.
At home, It can support your televisions, music system, decoder, PCs, internet modem.
Specifications:
Technology:
UPS type |
Off-Line |
Form factor |
Tower |
Input parameters:
Power |
480 VA |
Current frequency |
(50/60)±1Hz (Frequency self-adapt system) |
Output parameters:
Output voltage |
220 / 230V ± 10% |
Form voltage |
Stepped approximation to a sinewave |
Current frequency |
50/60 Hz ± 1% |
Switching time |
2-4 ms, including the determination of the time |
Automatic voltage regulation (AVR) |
1 step down, two steps up |
Protection and UPS equipment:
Surge Protection |
Yes |
Overloads protectio |
110% < Load percentage <120%, buzze beeps; load percentage >120%. output shuts off, buzzer beeps continuosly |
Protection for UPS input |
Fuse for overload protection and short circuit protection |
UPS protection for short circuit |
Immediate shutdown of the UPS using the input fuse |
Protect the phone, fax, modem, LAN |
No |
| Gamma 6 Hybrid
Technical features
MODEL Name – Gamma 6
Model Number – ONY-I-G6-48
Maximum PV Input Power – 6000W
Rated Output Power – 6000W
Gamma 6 Hybrid
• Pure sine wave output & Dual AC output
• Self-consumption and feed-in to the grid
• Built-in MPPT solar charger
• Programmable supply priority for PV, Battery or Grid
• User-adjustable charging current and voltage
• Programmable multiple operation modes: Grid-tie,off-grid and grid-tie with backup
• Detachable LCD panel
• Built-in Wi-Fi for mobile monitoring (APP is available)
• Supports USB on the go function
• Reserve BMS communication
• Parallel operation up to 9 units
SPECIFICATIONS
GRID TIE OPERATION (AC) / PV INPUT (DC) / HYBRID OPERATION
Power Rate/Nominal DC Voltage/Maximum DC Voltage - 360VDC/500VDC
Start-up Voltage/ Initial Feeding Voltage – 120VDC/150VDC
MPPT Voltage Range – 120VDC~150VDC/430VDC
Number of MPPT Trackers / Max Input Current - 1/27A
GRID TIE OPERATION / GRID OUTPUT (AC) / HYBRID OPERATION
Nominal Output Voltage - 220/230/240VAC
Output Voltage Range - 184 – 264.5 VAC or 195.5 – 253 VAC (Selectable)
Nominal Output Current - 26A
GRID TIE OPERATION / EFFICIENCY
Maximum Conversion Efficiency (DC/AC) - 95%
OFF-GRID OPERATION / AC INPUT / HYBRID OPERATION
AC Startup Voltage / Auto Restart Voltage – 120 - 140VAC / 180VAC
Acceptable Input Voltage Range - 90-280VAC or 170 - 280VAC
Frequency Range - 50Hz / 60Hz (Auto Sensing)
Maximum AC Input Current - 40A
OFF-GRID OPERATION / PV INPUT (DC)
Maximum DC Voltage - 500VDC
MPPT Voltage Range – 120VDC ~ 430VAC
Number of MPPT Trackers / Max Input Current - (1/27A)
OFF-GRID OPERATION / BATTERY MODE OUTPUT (AC)
Battery Mode Output (AC) - 220/230/240VAC
Output Waveform - Pure Sine Wave
Efficiency (DC to AC) - 93%
HYBRID OPERATION / BATTERY MODE OUTPUT
Nominal Output Voltage - 220/230/240VAC
Efficiency (DC to AC) - 93%
HYBRID OPERATION / BATTERY & CHARGER
Maximum DC Voltage - 48V
Maximum Solar Charging Current – 120A
Maximum AC Charging Current – 120A
Maximum Charging Current – 120A
GENERAL / PHYSICAL of Gamma 6 Hybrid
Dimension, D x W x H (mm) – 140 x 295 x 468
Net Weight – 14KG
GENERAL / INTERFACE
Parallel Function – Built in parallel kit up to 9 units
Communication Port – USB/RS-232/WiFi/Dry-Contact
GENERAL / ENVIRONMENT
Humidity – 0~ 90% RH (No Condensing)
Operating Temperature –  -10°C to 50°C | Beta 4.2 Hybrid Solar Inverter
Model name Beta 4.2KW
Max PV input Power - 6200
Rated output power - 4200
Maximum solar charger power - 140A
Grid Tie operation / PV input (DC)
Nominal DC voltage/ Max DC voltage - 360VvDC/500VDC
Start up Voltage/ Initial feeding voltage - 90DVC/120VDC
MPPT voltage range - 90-450VDC
Number of MPPT trackers / Max input current - 1/27A
Grid output (AC)
Nominal output voltage - 220/230/240VAC
output voltage range - 195-235VAC
Nominal output current - 18.2A
Power factor - 0.99
Feed-in Grid frequency range - 49Hz to 51Hz
Efficiency - 97%
Off-Grid operation / AC input
AC startup voltage / Auto restarting voltage - 120-140V
Acceptable input voltage range - 90-280VAC/ 170-280VAC
Maximum AC input Current - 30A
Nominal operating frequency 50/60Hz
Surge power - 8400VA
Off-Grid operation / PV input(DC)
Maximum DC voltage - 500vVDC
MPPT voltage range - 90-450VAC
Number of MPPT trackers / Max input current - (1/27)
Battery mode output AC
Nominal output voltage - 24V
Output wave form - Pure sin wave
Efficiency (DC to AC) - 94%
Battery & charger
Nominal DC voltage -24V
Maximum solar charger current - 140A
Maximum AC charging current - 100A
Physical features
Dimensions (D*Y*H) - 420 * 310 * 110
Net Weight (KGs) - 9.5
Interface - serial connection
communications - RS-232
Humidity - 0-90%
Operating temperature - (-10 to 50) | BLUE GATE 1530KVA UPS
Blue Gate 1530KVA UPS is efficient, durable and boasts of three LED indications that make it easy for you to understand as well as a
digitized microprocessor control that stabilizes the flow of power and overload protection that makes it not to affect any of your household appliances.
The energy saving function comes in a green and red color mode that lets you know when the UPS battery is full and
when it is also getting low to enable you switch off your appliances before it finally shut off.
Blue Gate 1530KVA UPS that provides an alternative power supply to connects with any electronic equipment when the primary power source is not available.
You could make use of the UPS for your electrical equipment with generators that are compatible with the voltage of the
UPS to enjoy your television, freezers, air conditioners and more without fluctuation of supply of power.
The UPS charges manually and automatically as you are making use of it when there is stable light or
with generator and is helpful in protecting our appliances from damages and have prevents serious hardware damage and