Description | Solar Charge Controller (60A)
- Model: MPPT 60A
- Max. Charge Current 60A
- System Voltage: 12v/24v/36v/48v
| SOLAR CHARGE CONTROLLER (100A)
- Model: MPPT 100A
- Max. Charge Current:100A
- System Voltage:12v/24v/36v/48v
| ALPHA 3.2KVA–3KW Off Grid
• Pure Sine wave Solar Inverter
• Output power factor : 0.8
• 24v system
• Maximum PV array power 3000W
• MPPT Range Operation Voltage 30-400VDC
• Maximum Charging Current 80A | Àmųmà Plus 1.5KVA (12V)
Model name – GA1512A
Capacity (VA) – 1500VA
Input Voltage (DC) – 12V
Nominal Voltage – 220VAC
Voltage Range – 154-265VAC (AC Model); 185-264VAC±3V(UPS Model)
Frequency 50/60Hz (Auto sensing)
Power Factor – 0.8 | SOLAR CHARGE CONTROLLER (80A)
- Model: MPPT 80A
- Max. Charge Current:80A
- System Voltage:12v/24v/36v/48v
| Grovolt Ricco Plus 2.5KVA
* Pure Sine Wave Inverter
* Inbuilt With Transformer which is a strong load ability.
* Wide Charge Current 20-30A
* High-efficiency design & Power saving mode to conserve energy.
* Auto-restart when AC recovering.
|
Content | Solar Charge Controller (60A)
Model: MPPT 60A
Max. Charge Current 60A
System Voltage: 12v/24v/36v/48v
Flexible
Max. PV Voltage (VoC): 150Vdc
Solar Operating Voltage: 20-150Vdc @12V
36-150Vdc @24v
48-150Vdc @36v
64-150Vdc @48v
PV Input Power: 12v: 800w
24v: 1600w
36v: 2400w
48v: 3200w
Operation Temperature -25~60°C | SOLAR CHARGE CONTROLLER (100A)
Model: MPPT 100A
Max. Charge Current:100A
System Voltage:12v/24v/36v/48v
Flexible
Max. PV Voltage (VoC):150Vdc
Solar Operating Voltage: 20-150Vdc @12V
36-150Vdc @24v
48-150Vdc @36v
64-150Vdc @48v
PV Input Power:12v: 1040w
24v: 2600w
36v: 3900w
48v: 5200w
Operation Temperature-25~60°C | ALPHA 3.2KVA–3KW Off Grid
• Pure Sine wave Solar Inverter
• Output power factor : 0.8
• 24v system
• Maximum PV array power 3000W
• MPPT Range Operation Voltage 30-400VDC
• Maximum Charging Current 80A
ALPHA 3.2KVA–3KW Off Grid
Model name – Alpha 3.2KVA
Model Number – Ony-I-A3.0-24
Rated Power – 3200VA/300W
AC Input Voltage – 230VAC
Selectable Voltage – Computers (170-280VAC)/ Appliances (90-280VAC)
Frequency range 50/60Hz (Auto sensing)
AC OUTPUT
AC Voltage Regulation – 230VAC +/-5%
Surge Power – 6400VA
Efficiency Peak – 98%
Transfer Time – 10ms
BATTERY & AC CHARGER
Battery Voltage – 24VDC
Floating Charge – 27VDC
Overcharge Protection – 33VDC
Maximum AC Charge Current – 60A
SOLAR CHARGER
Maximum PV Array power – 3000W
MPPT Range Operation Voltage – 30-400VDC
Max PV array open circuit – 400VDC
Maximum Charging Current – 80A | Àmųmà Plus 1.5KVA (12V)
• Support Lithium battery
• Support RS232 for WIFI (optional)
• Pure Sine Wave output
• Powerful Charge Rate Up to 90AMP
• DC Start & Automatic Self-Diagnostic Function
• High Efficiency Design & “Power Saving Mode” to Conserve Energy
• Auto restart when AC in recovering
• Smart battery charger design for optimized battery performance
• Selectable charging current based on applications
• AC input/DC input/Solar input optional priority
• Built-in Transformer
• Wall-Mounted
DESCRIPTION
SPECIFICATIONS
Model name – GA1512A
Capacity (VA) – 1500VA
Input Voltage (DC) – 12V
Nominal Voltage – 220VAC
Voltage Range – 154-265VAC (AC Model); 185-264VAC±3V(UPS Model)
Frequency 50/60Hz (Auto sensing)
Power Factor – 0.8
Rated Power 1200W
Voltage 220VAC
Frequency 50/60Hz
Waveform Pure Sinewave
Transfer time (AC to DC) <8ms
Transfer time (DC to AC) <8ms
Output Voltage Regulation ±10%
Bypass Mode Yes
Save mode Yes
Efficiency >98%
Input protection Circuit breaker
Output protection Circuit breaker
Battery Type AGM- Deep Cycle, Gel Up to 500Ah
Charging current 30A
Low Level disconnect (Selectable) 10V or 10.5V
PWM (Optional) Controller Voltage 15VDC - 30VDC
MPPT (Optional) Controller Voltage 15VDC - 30VDC
Maximum PV Array Power 400W
Maximum PV Array Open circuit Voltage PWM: 50VDC
Maximum Solar Charge current 30A
Protections Over load, Over temp, Ove charging, Battery low, Battery reverse connect, High AC voltage etc
LCD Indicator Status AC Input Voltage, AC Input Frequency, PV Voltage, PV Current
Output Voltage, Output Frequency, Battery Voltage, Load current etc.
LED Indicator Status AC Line in: Green / Inverter: Green / Charging: Yellow / Alarm: Red
Low battery alarm Audible alarm -5 sounds beeping
Overload alarm Audible alarm-continuous beeping
Fault Audible alarm-continuous beeping
Temperature 0 – 40°C
Humidity -10°C-90°C Non Condensing
Accoustic Noise (db) >55dB
Size L*W*H (mm) 325*263*123MM
Weight | SOLAR CHARGE CONTROLLER (80A)
Model: MPPT 80A
Max. Charge Current:80A
System Voltage:12v/24v/36v/48v
Flexible
Max. PV Voltage (VoC):150Vdc
Solar Operating Voltage: 20-150Vdc @12V
36-150Vdc @24v
48-150Vdc @36v
64-150Vdc @48v
PV Input Power:12v: 1040w
24v: 2080w
36v: 3120w
48v: 4160w
Operation Temperature-25~60°C | GROVALT RICCO PLUS 2.5KVA
Grovolt Ricco Plus 2.5KVA (12/24/48V) Off Grid Solar Inverter
* Pure Sine Wave Inverter
* Inbuilt With Transformer which is a strong load ability.
* Wide Charge Current 20-30A
* High-efficiency design & Power saving mode to conserve energy.
* Auto-restart when AC recovering.
* Smart battery charger design for optimized battery performance; With bypass /battery reverse protection / 6mill seconds transfer time / surge protection/input & output overload protection
DESCRIPTION
SPECIFICATIONS of GROVALT RICCO PLUS 2.5KVA
Model name – RP-2500
Input
Capacity – 2500VA
Voltage (DC) – 12/24/48V
Nominal Voltage – 220VAC/110VAC
Voltage Range – 154-265VAC/77-135VAC
Frequency 50/60Hz (Auto sensing)
OUTPUT
Watt 800W | 1200W | 2000W | 2800W | 4000W | 4800W | 5200W | 6400W | 8000W
Voltage – 220VAC/110VAC
Frequency - 50Hz to 60Hz
Waveform – Pure Sinewave
Transfer time (AC to DC) <8ms
Transfer time (DC to AC) <8ms
Output Voltage Regulation 10%rms
Bypass Mode Yes
Save mode Yes
Efficiency >98%
PROTECTION
Input protection Circuit breaker
Output protection Circuit breaker
BATTERY
BATTERY TYPE AGM- Deep Cycle Gel
Up to 500Ah
Charging current 20/10A |30/15/7A | 48/24/12A | 30/15A | 40/20A | 45/22A | 50/25A | 35A | 50/25/12A
Low level disconnect (10V or 10.5V) Ă— N N means the number of batteries in series
LCD INDICATOR STATUS Input AC/ Output AC
Battery DC, Output Load
Alarm, Fault
Battery Charge Level
Output Frequency
LED INDICATOR STATUS AC Line in: Green
Inverter: Green
Charging: Yellow
Alarm: Red
GROVALT RICCO PLUS 2.5KVAÂ Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Battery low alarm battery light discharge 11.5V*N; battery load discharge 11.5V*N@load<20%
11V*N@load>50% / 10.5V*N@load>50%
Battery low recovery battery light discharge 11.5V*N; battery load discharge 11.5V*N@load<20%
11.5V*N@load>50% / 11V*N@load>50%
DC low voltage shutdown battery light discharge 11.5V*N; battery load discharge 11.5V*N@load<20%
10.5V*N@load>50% / 10.5V*N@load>50%
DC high Voltage alarm & fault 16V*N
DC high Voltage recovery 15V*N
ALARM
Low battery alarm Audible alarm -1 beeping per second
Overload alarm Audible alarm-continuous beeping
Fault Audible alarm-continuous beeping
ENVIRONMENT
Temperature - (0 - 40)
Humidity - CO-95% Non Condensing
Fault – >55db |