Description | Grovolt Ricco Plus 2.5KVA
* Pure Sine Wave Inverter
* Inbuilt With Transformer which is a strong load ability.
* Wide Charge Current 20-30A
* High-efficiency design & Power saving mode to conserve energy.
* Auto-restart when AC recovering.
| Àmųmà Plus 6KVA (24V)
- Model name – GA6024A
- Capacity (VA) – 6000VA
- Input Voltage (DC) – 24V
- Nominal Voltage – 220VAC
- Voltage Range – 154-265VAC (AC Model); 185-264VAC±3V(UPS Model)
- Frequency 50/60Hz (Auto sensing)
- Power Factor – 0.8
| APC EASY UPS BV 650VA
- Output power capacity: 375 Watts / 650 VA
- Max Configurable Power (Watts): 375 Watts / 650 VA
- Nominal Output Voltage: 230V
- Output Frequency (not synced): 50/60 Hz +/-1 Hz
| Àmųmà Plus 2KVA (12/24V)
Model name – GA2024A
Capacity (VA) – 2000VA
Input Voltage (DC) – 12/24V
Nominal Voltage – 220VAC
Voltage Range – 154-265VAC (AC Model); 185-264VAC±3V(UPS Model)
Frequency 50/60Hz (Auto sensing)
Power Factor – 0.8 | Delta 8 Hybrid
• Operation Type: Off-Grid/On-Grid
• Sine wave Type: Pure, Power Factor 1.0
• Dual AC output for smart load management
• Battery Independent Design
• Wide PV input voltage range (90-450VDC)
• Built-in WiFi with IOS & Android APP
• Supports USB on the go function
• RGB Lightning for different working modes (Battery, Solar, Utility)
• With Parallel kits support up to 6 units | Grovolt Ricco Plus 3.5KVA (24/48V)
* Pure Sine Wave Inverter
* Inbuilt With Transformer which is a strong load ability.
* Wide Charge Current 20-30A
* High-efficiency design & Power saving mode to conserve energy.
* Auto-restart when AC recovering. |
Content | GROVALT RICCO PLUS 2.5KVA
Grovolt Ricco Plus 2.5KVA (12/24/48V) Off Grid Solar Inverter
* Pure Sine Wave Inverter
* Inbuilt With Transformer which is a strong load ability.
* Wide Charge Current 20-30A
* High-efficiency design & Power saving mode to conserve energy.
* Auto-restart when AC recovering.
* Smart battery charger design for optimized battery performance; With bypass /battery reverse protection / 6mill seconds transfer time / surge protection/input & output overload protection
DESCRIPTION
SPECIFICATIONS of GROVALT RICCO PLUS 2.5KVA
Model name – RP-2500
Input
Capacity – 2500VA
Voltage (DC) – 12/24/48V
Nominal Voltage – 220VAC/110VAC
Voltage Range – 154-265VAC/77-135VAC
Frequency 50/60Hz (Auto sensing)
OUTPUT
Watt 800W | 1200W | 2000W | 2800W | 4000W | 4800W | 5200W | 6400W | 8000W
Voltage – 220VAC/110VAC
Frequency - 50Hz to 60Hz
Waveform – Pure Sinewave
Transfer time (AC to DC) <8ms
Transfer time (DC to AC) <8ms
Output Voltage Regulation 10%rms
Bypass Mode Yes
Save mode Yes
Efficiency >98%
PROTECTION
Input protection Circuit breaker
Output protection Circuit breaker
BATTERY
BATTERY TYPE AGM- Deep Cycle Gel
Up to 500Ah
Charging current 20/10A |30/15/7A | 48/24/12A | 30/15A | 40/20A | 45/22A | 50/25A | 35A | 50/25/12A
Low level disconnect (10V or 10.5V) × N N means the number of batteries in series
LCD INDICATOR STATUS Input AC/ Output AC
Battery DC, Output Load
Alarm, Fault
Battery Charge Level
Output Frequency
LED INDICATOR STATUS AC Line in: Green
Inverter: Green
Charging: Yellow
Alarm: Red
GROVALT RICCO PLUS 2.5KVA Battery low alarm battery light discharge 11.5V*N; battery load discharge 11.5V*N@load<20%
11V*N@load>50% / 10.5V*N@load>50%
Battery low recovery battery light discharge 11.5V*N; battery load discharge 11.5V*N@load<20%
11.5V*N@load>50% / 11V*N@load>50%
DC low voltage shutdown battery light discharge 11.5V*N; battery load discharge 11.5V*N@load<20%
10.5V*N@load>50% / 10.5V*N@load>50%
DC high Voltage alarm & fault 16V*N
DC high Voltage recovery 15V*N
ALARM
Low battery alarm Audible alarm -1 beeping per second
Overload alarm Audible alarm-continuous beeping
Fault Audible alarm-continuous beeping
ENVIRONMENT
Temperature - (0 - 40)
Humidity - CO-95% Non Condensing
Fault – >55db | Àmųmà Plus 6KVA (24V)
• Support Lithium battery
• Support RS232 for WIFI (optional)
• Pure Sine Wave output
• Powerful Charge Rate Up to 90AMP
• DC Start & Automatic Self-Diagnostic Function
• High Efficiency Design & “Power Saving Mode” to Conserve Energy
• Auto restart when AC in recovering
• Smart battery charger design for optimized battery performance
• Selectable charging current based on applications
• AC input/DC input/Solar input optional priority
• Built-in Transformer
• Wall-Mounted
DESCRIPTION
Specification Of Àmųmà Plus 6KVA (24V)
Model name – GA6024A
Capacity (VA) – 6000VA
Input Voltage (DC) – 24V
Nominal Voltage – 220VAC
Voltage Range – 154-265VAC (AC Model); 185-264VAC±3V(UPS Model)
Frequency 50/60Hz (Auto sensing)
Power Factor – 0.8
Rated Power 4800W
Voltage 220VAC
Frequency 50/60Hz
Waveform Pure Sinewave
Transfer time (AC to DC) <8ms
Transfer time (DC to AC) <8ms
Output Voltage Regulation ±10%
Bypass Mode Yes
Save mode Yes
Efficiency >98%
Input protection Circuit breaker
Output protection Circuit breaker
Battery Type AGM- Deep Cycle, Gel Up to 500Ah
Charging current 60A
Low Level disconnect (Selectable) 20V or 21V
PWM (Optional) Controller Voltage 30VDC - 60VDC
MPPT (Optional) Controller Voltage 30VDC - 60VDC
Maximum PV Array Power 1600W
Maximum PV Array Open circuit Voltage PWM: 150VDC, MPPT:150VDC
Maximum Solar Charge current 100A
Protections Over load, Over temp, Over charging, Battery low, Battery reverse connect, High AC voltage etc
LCD Indicator Status AC Input Voltage, AC Input Frequency, PV Voltage, PV Current
Output Voltage, Output Frequency, Battery Voltage, Load current etc.
LED Indicator Status AC Line in: Green / Inverter: Green / Charging: Yellow / Alarm: Red
Low battery alarm Audible alarm -5 sounds beeping
Overload alarm Audible alarm-continuous beeping
Fault Audible alarm-continuous beeping
Temperature 0 – 40°C
Humidity -10°C-90°C Non Condensing
Accoustic Noise (db) >55dB
Size L*W*H (mm) 470*335*210MM
Weight 29 | APC EASY UPS BV 650VA
APC EASY UPS BV 650VA, AVR, Universal Outlet, 230V
Best Value UPS with Battery Backup & Surge Protection for Electronics and Computers
Output
Max Configurable Power (Watts):375Watts / 650VA
Output Frequency (not synced):50/60 Hz +/-1 Hz
Topology:Line Interactive
Waveform type: Stepped approximation to a sinewave
Transfer Time:6ms typical : 10ms maximum
Input
Input frequency:50/60 Hz +/- 5 Hz (auto sensing)
Number of Power Cords:1
Batteries & Runtime
Battery type:Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
Expected Battery Life (years):3 – 5
Communications & Management
Control panel:LED Status display with On Line : On Battery
Audible Alarm: Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm
Net Weight:4.5KG
FEATURES OF APC EASY UPS BV 650VA
- Provides temporary battery power when the utility power is out
- Protect equipment with input transformer blocks without blocking access to other receptacles.
- Slim, modern design can be upright, flat, or wall-mounted to comfortably fit any electronics set-up and complement home décor.
- Preserves battery life and maximizes runtime by correcting low voltages without discharging the battery.
| Àmųmà Plus 2KVA (12/24V)
• Support Lithium battery
• Support RS232 for WIFI (optional)
• Pure Sine Wave output
• Powerful Charge Rate Up to 90AMP
• DC Start & Automatic Self-Diagnostic Function
• High Efficiency Design & “Power Saving Mode” to Conserve Energy
• Auto restart when AC in recovering
• Smart battery charger design for optimized battery performance
• Selectable charging current based on applications
• AC input/DC input/Solar input optional priority
• Built-in Transformer
• Wall-Mounted
DESCRIPTION
SPECIFICATIONS
Model name – GA2024A
Capacity (VA) – 2000VA
Input Voltage (DC) – 12/24V
Nominal Voltage – 220VAC
Voltage Range – 154-265VAC (AC Model); 185-264VAC±3V(UPS Model)
Frequency 50/60Hz (Auto sensing)
Power Factor – 0.8
Rated Power 1600W
Voltage 220VAC
Frequency 50/60Hz
Waveform Pure Sinewave
Transfer time (AC to DC) <8ms
Transfer time (DC to AC) <8ms
Output Voltage Regulation ±10%
Bypass Mode Yes
Save mode Yes
Efficiency >98%
Input protection Circuit breaker
Output protection Circuit breaker
Battery Type AGM- Deep Cycle, Gel Up to 500Ah
Charging current 20A/30A
Low Level disconnect (Selectable) 20V or 21V
PWM (Optional) Controller Voltage
MPPT (Optional) Controller Voltage 15VDC - 30VDC
Maximum PV Array Power 1600W
Maximum PV Array Open circuit Voltage PWM: 105VDC, MPPT:150VDC
Maximum Solar Charge current 60A
Protections Over load, Over temp, Over charging, Battery low, Battery reverse connect, High AC voltage etc
LCD Indicator Status AC Input Voltage, AC Input Frequency, PV Voltage, PV Current
Output Voltage, Output Frequency, Battery Voltage, Load current etc.
LED Indicator Status AC Line in: Green / Inverter: Green / Charging: Yellow / Alarm: Red
Low battery alarm Audible alarm -5 sounds beeping
Overload alarm Audible alarm-continuous beeping
Fault Audible alarm-continuous beeping
Temperature 0 – 40°C
Humidity -10°C-90°C Non Condensing
Accoustic Noise (db) >55dB
Size L*W*H (mm) 470*335*210MM
Weight 17 | Delta 8.2 Hybrid
Technical features
MODEL Name - Delta 8.2
Model Number - ONY-I-D8.2-48
Rated Power - 8200VA/8200W
PARALLEL CAPABILITY - Yes, up to 6 units
Delta 8 Hybrid
• Operation Type: Off-Grid/On-Grid
• Sine wave Type: Pure, Power Factor 1.0
• Dual AC output for smart load management
• Battery Independent Design
• Wide PV input voltage range (90-450VDC)
• Built-in WiFi with IOS & Android APP
• Supports USB on the go function
• RGB Lightning for different working modes (Battery, Solar, Utility)
• With Parallel kits support up to 6 units
INPUT
Voltage - 230 VAC
Selectable Voltage Range - 170-280 VAC (For Personal Computers)/90-280 VAC (For Home Appliances)
Frequency Range - 50 Hz/60 Hz (Auto sensing)
OUTPUT
AC Voltage Regulation (Batt.Mode) - 230VAC+/-5%
Surge Power - 16400VA
Efficiency (Peak) - 90% ~ 93%
Transfer Time - 15 ms (For Personal Computers) ; 20 ms (For Home Appliances)
Waveform - Pure sine wave
No Load Power Consumption - <70wW
DC Voltage (Optional) - 12 VDC +/- 5%,100W
BATTERY
Battery Voltage - 48 VDC
Floating Charge Voltage - 54 VDC
Overcharge Protection - 66 VDC
SOLAR CHARGER & AC CHARGER of Delta 8.2 Hybrid
Solar Charger Type – MPPT
Maximum PV Array Power – 8200W (4100W x 2)
MPPT Range @ Operating Voltage – 90 ~ 450 VDC
Maximum PV Array Open Circuit Voltage – 500 VDC
Maxmum Solar Charge Current – 120 A
Maximum AC Charge Current – 120 A
Maximum Charge Current – 120 A
PHYSICAL
Dimension, D x W x H (mm) – 147.4 x 432.5 x 553.6
Net Weight (kgs) – 18.4
Communication Interface – USB/RS232/RS485/WiFi/Dry-contact
OPERATING ENVIRONMENT
Humidity: 5% to 95% to Relative Humidity (Non-Condensing)
Operating Temperature – 10°C to 50°C
Storage Temperature – 15°C to 60°C
Compliance Safety – CE
| Grovolt Ricco Plus 3.5KVA (24/48V)
* Pure Sine Wave Inverter
* Inbuilt With Transformer which is a strong load ability.
* Wide Charge Current 20-30A
* High-efficiency design & Power saving mode to conserve energy.
* Auto-restart when AC recovering.
* Smart battery charger design for optimized battery performance; With bypass /battery reverse protection / 6mill seconds transfer time / surge protection/input & output overload protection
DESCRIPTION
SPECIFICATIONS of Grovolt Ricco Plus 3.5KVA (24/48V)
Model name – RP-3500 AND RP-3548
Input
Capacity – 3500VA
Voltage (DC) – 24/48V
Nominal Voltage – 220VAC/110VAC
Voltage Range – 154-265VAC/77-135VAC
Frequency 50/60Hz (Auto sensing)
OUTPUT
Watt 800W | 1200W | 2000W | 2800W | 4000W | 4800W | 5200W | 6400W | 8000W
Voltage – 220VAC/110VAC
Frequency - 50Hz to 60Hz
Waveform – Pure Sinewave
Transfer time (AC to DC) <8ms
Transfer time (DC to AC) <8ms
Output Voltage Regulation 10%rms
Bypass Mode Yes
Save mode Yes
Efficiency >98%
PROTECTION
Input protection Circuit breaker
Output protection Circuit breaker
BATTERY
BATTERY TYPE AGM- Deep Cycle Gel
Up to 500Ah
Charging current 20/10A |30/15/7A | 48/24/12A | 30/15A | 40/20A | 45/22A | 50/25A | 35A | 50/25/12A
Low level disconnect (10V or 10.5V) × N N means the number of batteries in series
LCD INDICATOR STATUS Input AC/ Output AC
Battery DC, Output Load
Alarm, Fault
Battery Charge Level
Output Frequency
LED INDICATOR STATUS AC Line in: Green
Inverter: Green
Charging: Yellow
Alarm: Red
Grovolt Ricco Plus 3.5KVA (24/48V)
Battery low alarm battery light discharge 11.5V*N; battery load discharge 11.5V*N@load<20%
11V*N@load>50% / 10.5V*N@load>50%
Battery low recovery battery light discharge 11.5V*N; battery load discharge 11.5V*N@load<20%
11.5V*N@load>50% / 11V*N@load>50%
DC low voltage shutdown battery light discharge 11.5V*N; battery load discharge 11.5V*N@load<20%
10.5V*N@load>50% / 10.5V*N@load>50%
DC high Voltage alarm & fault 16V*N
DC high Voltage recovery 15V*N
ALARM
Low battery alarm Audible alarm -1 beeping per second
Overload alarm Audible alarm-continuous beeping
Fault Audible alarm-continuous beeping
ENVIRONMENT
Temperature - (0 - 40)
Humidity - CO-95% Non Condensing
Fault – >55db |
Reviews
There are no reviews yet.