Description | ORVAL TRI 10
• Pure SineWave Solar Inverter
• On-grid/Off-Grid.
• Output power Factor 1.0.
• Battery Independent Design
• Built-in 120A MPPT Solar charger.
• Wide PV input voltage range (90-450VDC).
• Built-in anti-dust kit.
• Smart battery charger design
• 3 phase in/3 phase out | Beta 6.2 Hybrid Solar Inverter
• Pure sine wave inverter
• Output power factor:1
• Battery independent design
• RGB lighting for different operation modes
• OFF/ON Grid Operation types
• Built-in 120 /140Ah solar charger
• High PV input range (90VDC to 500VC)
• RGB LED three colors as per operation mode
• Max PV input power 6500 | Solar Charge Controller (60A)
- Model: MPPT 60A
- Max. Charge Current 60A
- System Voltage: 12v/24v/36v/48v
| Grovolt Ricco Plus 2.5KVA
* Pure Sine Wave Inverter
* Inbuilt With Transformer which is a strong load ability.
* Wide Charge Current 20-30A
* High-efficiency design & Power saving mode to conserve energy.
* Auto-restart when AC recovering.
| Àmųmà Plus 6KVA (24V)
- Model name – GA6024A
- Capacity (VA) – 6000VA
- Input Voltage (DC) – 24V
- Nominal Voltage – 220VAC
- Voltage Range – 154-265VAC (AC Model); 185-264VAC±3V(UPS Model)
- Frequency 50/60Hz (Auto sensing)
- Power Factor – 0.8
| Àmųmà Plus 1.5KVA (12V)
Model name – GA1512A
Capacity (VA) – 1500VA
Input Voltage (DC) – 12V
Nominal Voltage – 220VAC
Voltage Range – 154-265VAC (AC Model); 185-264VAC±3V(UPS Model)
Frequency 50/60Hz (Auto sensing)
Power Factor – 0.8 |
Content | ORVAL TRI 10
DESCRIPTION
SPECIFICATIONS
Model name : TRI-10KW
Phase Type 3 Phase in / 3 Phase Out
Maximum PV input Power 14850W
Rated Output Power 10000W
Maximum Charging Power 9600W
Nominal DC Voltage /Maximum DC Voltage 720VDC / 900VDC
Start-up Voltage / Initial Feeding Voltage
MMPT Voltage Range 400VDC / 800VDC
Number of MPPT Trackers / Maximum Input Current 2/2* 18.6A
Nominal Output Voltage 230VAC (P-N), 400VAC (P-P)
Output Voltage Range 184VAC to 265VAC per phase
Nominal Output Current
Power Factor <0.99
European Efficiency 96%
Maximum Conversion Efficiency 96%
AC Startup Voltage / Auto Restart Voltage 120VAC to 140VAC P-P/ 180 VAC P-P
Acceptable Input Voltage Range 170VAC to 280VAC per phase
Maximum AC Input Current 40A
Maximum DC Voltage 900VDC
MPPT Voltage Range 400VDC to 800VDC
Number of MPPT Trackers / Maximum Input Current
Nominal Output Voltage 230VAC (P-N), 400VAC (P-P)
Output Waveform Pure Sinewave
Efficiency (DC to AC) 91%
Nominal DC Voltage /Maximum DC Voltage 720VDC / 900VDC
Start-up Voltage / Initial Feeding Voltage 320VDC / 350VDC
MPPT Voltage Range 400VDC / 800VDC
Number of MPPT Trackers / Maximum Input Current 2/2* 18.6A
Nominal Output Voltage 230VAC (P-N), 400VAC (P-P)
Output Voltage Range 184VAC to 265VAC Per Phase
Nominal Output Current 14.5A Per Phase
AC Startup Voltage / Auto Restart Voltage 120-140VAC P-P/ 180 VAC P-P
Acceptable Input Voltage Range 170 VAC to 280 VAC Per Phase
Maximum AC Input Current 40A
Nominal Output Voltage 230VAC (P-N), 400VAC (P-P)
Efficiency (DC to AC) 91%
Nominal DC Voltage 48VDC
Maximum Charging Current Default 60A, (10A to 200A adjustable)
Communication Port RS-232 / USB
Intelligent Slot Optional SNMP, Modbus and As400 Card
Dimensions (D*W*L: mm) and Weight (KG) 167.2*500*622, 40KG
Humidity 0 to 90% (non condensing
Operation temperature 0 to 55
Altitude 0 to 1000 Meter | Beta 6.2 Hybrid Solar Inverter
Model name Beta 6.2KW
Max PV input Power - 6500
Rated output power - 6200
Maximum solar charger power - 120A
Grid Tie operation / PV input (DC)
Nominal DC voltage/ Max DC voltage - 360VvDC/500VDC
Start up Voltage/ Initial feeding voltage - 90DVC/120VDC
MPPT voltage range - 90-450VDC
Number of MPPT trackers / Max input current - 1/27A
Grid output (AC)
Nominal output voltage - 220/230/240VAC
output voltage range - 195-235VAC
Nominal output current - 27A
Power factor - 0.99
Feed-in Grid frequency range - 49Hz to 51Hz
Efficiency - 97%
Off-Grid operation / AC input
AC startup voltage / Auto restarting voltage - 180V
Acceptable input voltage range - 90-280VAC/ 170-280VAC
Maximum AC input Current - 40A
Nominal operating frequency 50/60Hz
Surge power - 12400VA
Off-Grid operation / PV input(DC)
Maximum DC voltage - 500vVDC
MPPT voltage range - 90-450VAC
Number of MPPT trackers / Max input current - (1/27)
Battery mode output AC
Nominal output voltage - 48V
Output wave form - Pure sin wave
Efficiency (DC to AC) - 94%
Battery & charger
Nominal DC voltage -48V
Maximum solar charger current - 120A
Maximum AC charging current - 100A
Physical features
Dimensions (D*Y*H) - 420 * 310 * 110
Net Weight (KGs) - 10.5
Interface - serial connection
communications - RS-232
Humidity - 0-90%
Operating temperature - (-10 to 50) | Solar Charge Controller (60A)
Model: MPPT 60A
Max. Charge Current 60A
System Voltage: 12v/24v/36v/48v
Flexible
Max. PV Voltage (VoC): 150Vdc
Solar Operating Voltage: 20-150Vdc @12V
36-150Vdc @24v
48-150Vdc @36v
64-150Vdc @48v
PV Input Power: 12v: 800w
24v: 1600w
36v: 2400w
48v: 3200w
Operation Temperature -25~60°C | GROVALT RICCO PLUS 2.5KVA
Grovolt Ricco Plus 2.5KVA (12/24/48V) Off Grid Solar Inverter
* Pure Sine Wave Inverter
* Inbuilt With Transformer which is a strong load ability.
* Wide Charge Current 20-30A
* High-efficiency design & Power saving mode to conserve energy.
* Auto-restart when AC recovering.
* Smart battery charger design for optimized battery performance; With bypass /battery reverse protection / 6mill seconds transfer time / surge protection/input & output overload protection
DESCRIPTION
SPECIFICATIONS of GROVALT RICCO PLUS 2.5KVA
Model name – RP-2500
Input
Capacity – 2500VA
Voltage (DC) – 12/24/48V
Nominal Voltage – 220VAC/110VAC
Voltage Range – 154-265VAC/77-135VAC
Frequency 50/60Hz (Auto sensing)
OUTPUT
Watt 800W | 1200W | 2000W | 2800W | 4000W | 4800W | 5200W | 6400W | 8000W
Voltage – 220VAC/110VAC
Frequency - 50Hz to 60Hz
Waveform – Pure Sinewave
Transfer time (AC to DC) <8ms
Transfer time (DC to AC) <8ms
Output Voltage Regulation 10%rms
Bypass Mode Yes
Save mode Yes
Efficiency >98%
PROTECTION
Input protection Circuit breaker
Output protection Circuit breaker
BATTERY
BATTERY TYPE AGM- Deep Cycle Gel
Up to 500Ah
Charging current 20/10A |30/15/7A | 48/24/12A | 30/15A | 40/20A | 45/22A | 50/25A | 35A | 50/25/12A
Low level disconnect (10V or 10.5V) × N N means the number of batteries in series
LCD INDICATOR STATUS Input AC/ Output AC
Battery DC, Output Load
Alarm, Fault
Battery Charge Level
Output Frequency
LED INDICATOR STATUS AC Line in: Green
Inverter: Green
Charging: Yellow
Alarm: Red
GROVALT RICCO PLUS 2.5KVA Battery low alarm battery light discharge 11.5V*N; battery load discharge 11.5V*N@load<20%
11V*N@load>50% / 10.5V*N@load>50%
Battery low recovery battery light discharge 11.5V*N; battery load discharge 11.5V*N@load<20%
11.5V*N@load>50% / 11V*N@load>50%
DC low voltage shutdown battery light discharge 11.5V*N; battery load discharge 11.5V*N@load<20%
10.5V*N@load>50% / 10.5V*N@load>50%
DC high Voltage alarm & fault 16V*N
DC high Voltage recovery 15V*N
ALARM
Low battery alarm Audible alarm -1 beeping per second
Overload alarm Audible alarm-continuous beeping
Fault Audible alarm-continuous beeping
ENVIRONMENT
Temperature - (0 - 40)
Humidity - CO-95% Non Condensing
Fault – >55db | Àmųmà Plus 6KVA (24V)
• Support Lithium battery
• Support RS232 for WIFI (optional)
• Pure Sine Wave output
• Powerful Charge Rate Up to 90AMP
• DC Start & Automatic Self-Diagnostic Function
• High Efficiency Design & “Power Saving Mode” to Conserve Energy
• Auto restart when AC in recovering
• Smart battery charger design for optimized battery performance
• Selectable charging current based on applications
• AC input/DC input/Solar input optional priority
• Built-in Transformer
• Wall-Mounted
DESCRIPTION
Specification Of Àmųmà Plus 6KVA (24V)
Model name – GA6024A
Capacity (VA) – 6000VA
Input Voltage (DC) – 24V
Nominal Voltage – 220VAC
Voltage Range – 154-265VAC (AC Model); 185-264VAC±3V(UPS Model)
Frequency 50/60Hz (Auto sensing)
Power Factor – 0.8
Rated Power 4800W
Voltage 220VAC
Frequency 50/60Hz
Waveform Pure Sinewave
Transfer time (AC to DC) <8ms
Transfer time (DC to AC) <8ms
Output Voltage Regulation ±10%
Bypass Mode Yes
Save mode Yes
Efficiency >98%
Input protection Circuit breaker
Output protection Circuit breaker
Battery Type AGM- Deep Cycle, Gel Up to 500Ah
Charging current 60A
Low Level disconnect (Selectable) 20V or 21V
PWM (Optional) Controller Voltage 30VDC - 60VDC
MPPT (Optional) Controller Voltage 30VDC - 60VDC
Maximum PV Array Power 1600W
Maximum PV Array Open circuit Voltage PWM: 150VDC, MPPT:150VDC
Maximum Solar Charge current 100A
Protections Over load, Over temp, Over charging, Battery low, Battery reverse connect, High AC voltage etc
LCD Indicator Status AC Input Voltage, AC Input Frequency, PV Voltage, PV Current
Output Voltage, Output Frequency, Battery Voltage, Load current etc.
LED Indicator Status AC Line in: Green / Inverter: Green / Charging: Yellow / Alarm: Red
Low battery alarm Audible alarm -5 sounds beeping
Overload alarm Audible alarm-continuous beeping
Fault Audible alarm-continuous beeping
Temperature 0 – 40°C
Humidity -10°C-90°C Non Condensing
Accoustic Noise (db) >55dB
Size L*W*H (mm) 470*335*210MM
Weight 29 | Àmųmà Plus 1.5KVA (12V)
• Support Lithium battery
• Support RS232 for WIFI (optional)
• Pure Sine Wave output
• Powerful Charge Rate Up to 90AMP
• DC Start & Automatic Self-Diagnostic Function
• High Efficiency Design & “Power Saving Mode” to Conserve Energy
• Auto restart when AC in recovering
• Smart battery charger design for optimized battery performance
• Selectable charging current based on applications
• AC input/DC input/Solar input optional priority
• Built-in Transformer
• Wall-Mounted
DESCRIPTION
SPECIFICATIONS
Model name – GA1512A
Capacity (VA) – 1500VA
Input Voltage (DC) – 12V
Nominal Voltage – 220VAC
Voltage Range – 154-265VAC (AC Model); 185-264VAC±3V(UPS Model)
Frequency 50/60Hz (Auto sensing)
Power Factor – 0.8
Rated Power 1200W
Voltage 220VAC
Frequency 50/60Hz
Waveform Pure Sinewave
Transfer time (AC to DC) <8ms
Transfer time (DC to AC) <8ms
Output Voltage Regulation ±10%
Bypass Mode Yes
Save mode Yes
Efficiency >98%
Input protection Circuit breaker
Output protection Circuit breaker
Battery Type AGM- Deep Cycle, Gel Up to 500Ah
Charging current 30A
Low Level disconnect (Selectable) 10V or 10.5V
PWM (Optional) Controller Voltage 15VDC - 30VDC
MPPT (Optional) Controller Voltage 15VDC - 30VDC
Maximum PV Array Power 400W
Maximum PV Array Open circuit Voltage PWM: 50VDC
Maximum Solar Charge current 30A
Protections Over load, Over temp, Ove charging, Battery low, Battery reverse connect, High AC voltage etc
LCD Indicator Status AC Input Voltage, AC Input Frequency, PV Voltage, PV Current
Output Voltage, Output Frequency, Battery Voltage, Load current etc.
LED Indicator Status AC Line in: Green / Inverter: Green / Charging: Yellow / Alarm: Red
Low battery alarm Audible alarm -5 sounds beeping
Overload alarm Audible alarm-continuous beeping
Fault Audible alarm-continuous beeping
Temperature 0 – 40°C
Humidity -10°C-90°C Non Condensing
Accoustic Noise (db) >55dB
Size L*W*H (mm) 325*263*123MM
Weight |
Reviews
There are no reviews yet.